Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Echocardiography ; 41(3): e15777, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38526991

RESUMEN

INTRODUCTION: Cardiac sarcoidosis (CS) is commonly diagnosed based on clinical criteria and abnormalities in noninvasive imaging reported in patients with biopsy-proven extracardiac sarcoidosis. Electrocardiogram and two-dimensional echocardiography have a low sensitivity for CS detection. Cardiovascular magnetic resonance imaging (CMR) and positron emission tomography (PET) have limitations in terms of cost and availability. OBJECTIVES: This study aimed to assess the usefulness of left ventricular longitudinal strain, measured using two-dimensional speckle tracking echocardiography (STE), for the prediction of late gadolinium enhancement (LGE) presence in CMR in patients with biopsy-proven sarcoidosis. PATIENTS AND METHODS: A total of 119 patients with biopsy-proven extracardiac sarcoidosis were divided, according to the clinical criteria proposed by the 2014 Heart Rhythm Society expert consensus statement (HRS 2014), into two groups: 43 individuals with "probable cardiac sarcoidosis", CS(+) and 76 individuals without cardiac sarcoidosis, CS (-). Data from echocardiography, CMR, 12-lead ECG and 24 h Holter monitoring were analyzed. RESULTS: Left ventricular global longitudinal strain (LV-GLS) was slightly reduced in the entire sarcoidosis group (-18.61± 2.96), no difference between the CS (+) and CS (-) subgroups was found (-18.0% ± 3.2% and -18.9% ± 2.8%, respectively; p = .223). No cut-off value for LV-GLS was identified that could predict the presence of LGE. Segmental longitudinal strain impairment partially correlated with the presence of LGE on CMR. CONCLUSIONS: In our cohort of sarcoidosis patients, segmental longitudinal strain proved more helpful in the diagnostic process than LV-GLS. The ultimate role of STE in the diagnosis of CS remains to be established.


Asunto(s)
Cardiomiopatías , Miocarditis , Sarcoidosis , Humanos , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/patología , Medios de Contraste , Gadolinio , Ecocardiografía/métodos , Sarcoidosis/diagnóstico , Sarcoidosis/diagnóstico por imagen , Biopsia , Imagen por Resonancia Cinemagnética/métodos
2.
Kardiol Pol ; 82(2): 175-182, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38374779

RESUMEN

BACKGROUND: Chronic heart failure (CHF) is a major healthcare problem. However, there are no epidemiological studies assessing the prevalence of CHF in the general population with diagnosis based on algorithms recommended for clinical practice. AIM: The aim of the HF-Pomorskie survey was to assess the prevalence of three basic components of the 2016 ESC diagnostic algorithm for CHF (symptoms, N-terminal pro B-type natriuretic peptide [NT-proBNP], and abnormalities on echocardiography) and to determine whether this algorithm may be applicable to studies in general population samples. METHODS: The study was performed in a representative sample of 313 adults (170 women and 143 men) aged between 20 and 90 years (mean 55.2 years [15.3]) in Northern Poland. A questionnaire to determine New York Heart Association [NYHA] class, laboratory tests including NT-proBNP, as well as transthoracic echocardiography and spirometry examinations were performed in all subjects. RESULTS: Dyspnea (NYHA class II-IV) was reported by 13.7% of recruited participants. Dyspnea and elevated levels of NT-proBNP (>125 pg/ml) were found in 7.7% of all examined subjects, while dyspnea, elevated NT-proBNP levels accompanied by systolic or diastolic abnormalities on echocardiography occurred in 4.8%. In the group without dyspnea (86.3% of all examined subjects), every sixth subject had an elevated level of NT-proBNP. On the other hand, 5.8% of studied subjects reported a previous diagnosis of CHF, which was confirmed using the current ESC algorithm in 78% of them. CONCLUSIONS: The prevalence of CHF assessed by the 2016 ESC diagnostic algorithm in the representative sample of adults was equal to 4.8%. The clinical algorithm for the diagnosis of CHF is fully applicable to the representative surveys in the general population. However, due to logistic and economic factors, echocardiography examination and NT-proBNP determination can be limited to patients reporting dyspnea or previous diagnosis of CHF.


Asunto(s)
Insuficiencia Cardíaca , Masculino , Adulto , Humanos , Femenino , Adulto Joven , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Prevalencia , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/epidemiología , Enfermedad Crónica , Algoritmos , Disnea/diagnóstico , Disnea/epidemiología
4.
Cardiol J ; 30(1): 73-81, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-35470416

RESUMEN

BACKGROUND: The comprehensive assessment of right ventricular (RV) performance is of paramount importance because it is has been recognized as a strong prognostic factor in a variety of clinical settings. The aim herein was to evaluate the usefulness of RV longitudinal strain imaging by speckle-tracking echocardiography (STE) in daily clinical practice, especially in the context of RV systolic function and its changes after acute coronary syndrome (ACS). METHODS: This prospective study enrolled 63 patients with ischemic injury (left ventricular ejection fraction [LVEF] ≤ 45%). Additionally, a subgroup was created: patients with ACS treated with successful percutaneous coronary intervention. The clinical and echocardiographic parameters, including STE, were analyzed. RESULTS: Significant correlations for both RV free-wall (RVFWSL) and four-chamber (RV4CSL) longitudinal strain evaluated by STE with New York Heart Association class, LVEF, E/E' ratio, as well as conventional parameters of RV function were found. RVFWSL was able to detect subtle RV functional abnormalities, unreachable for traditional indices. RV recovery after ACS was not related to higher LVEF but better contractility of the interventricular septum (IVS) assessed by STE. CONCLUSIONS: Right ventricular strain proved to be a useful two-dimensional echocardiographic method to detect impaired RV performance, which showed a significant relationship with clinical and other echocardiographic indices. The IVS played a vital role in RV recovery among ACS survivors.


Asunto(s)
Disfunción Ventricular Izquierda , Disfunción Ventricular Derecha , Humanos , Ventrículos Cardíacos/diagnóstico por imagen , Volumen Sistólico , Función Ventricular Izquierda , Estudios Prospectivos , Ecocardiografía/métodos , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/etiología , Función Ventricular Derecha , Disfunción Ventricular Derecha/diagnóstico por imagen , Disfunción Ventricular Derecha/etiología
5.
Diagnostics (Basel) ; 12(11)2022 Oct 28.
Artículo en Inglés | MEDLINE | ID: mdl-36359463

RESUMEN

Background: Haemochromatosis (HCH), a common genetic disorder with variable penetrance, results in progressive but understudied iron overload. We prospectively evaluated organ iron loading and cardiac function in a tertiary center HCH cohort. Methods: 42 HCH patients (47 ± 14 years) and 36 controls underwent laboratory workup and cardiac magnetic resonance (CMR), including T1 and T2* mapping. Results: Myocardial T2* (myoT2*), myocardial T1 (myoT1) and liver T2* (livT2*) were lower in patients compared to controls (33 ± 4 ms vs. 36 ± 3 ms [p = 0.004], 964 ± 33 ms vs. 979 ± 25 ms [p = 0.028] and 21 ± 10 ms vs. 30 ± 5 ms [p < 0.001], respectively). MyoT2* did not reach the threshold of clinically significant iron overload (<20 ms), in any of the patients. In 22 (52.4%) patients, at least one of the tissue parameters was reduced. Reduced myocardial T2* and/or T1 were found in 10 (23.8%) patients, including 4 pts with normal livT2*. LivT2* was reduced in 18 (42.9%) patients. MyoT1 and livT2* inversely correlated with ferritin (rs = −0.351 [p = 0.028] and rs = −0.602 [p < 0.001], respectively). LivT2* by a dedicated sequence and livT2* by cardiac T2* mapping showed good agreement (ICC = 0.876 p < 0.001). Conclusions: In contemporary hemochromatosis, significant myocardial iron overload is rare. Low myocardial T2* and/or T1 values may warrant closer follow-up for accelerated myocardial iron overload even in patients without overt liver overload. Cardiac T2* mapping sequence allows for liver screening at the time of CMR.

8.
Microvasc Res ; 138: 104216, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34182004

RESUMEN

BACKGROUND: Familial hypercholesterolemia (FH) is a genetic lipid disorder leading to accelerated atherosclerosis, premature cardiovascular disease and death. Microvascular endothelial dysfunction is one of the earliest vascular pathology manifestations and may precede symptomatic atherosclerosis. METHODS: In this paper, microvascular endothelial function was assessed in FH patients and healthy controls using flow mediated skin fluorescence (FMSF), based on measurements of nicotinamide adenine dinucleotide fluorescence intensity during brachial artery occlusion (ischemic response, IR) and immediately after occlusion (hyperemic response, HR). Low-density lipoprotein cholesterol (LDL-C) and total cholesterol (TC) were used to assess its relation with microvascular parameters evaluated in vivo. RESULTS: LDL-C levels were significantly correlated to both HRmax (r = -0.548, p = 0.001) and HRindex (r = -0.514, p = 0.003). Similarly, there was a significant inverse correlation of TC levels and both HRmax (r = -0.538, p = 0.002) and HRindex (r = -0.512, p = 0.003). All FMSF parameters were found lower in FH patients compared to age- and sex-matched healthy controls. Hyperemic response (HRmax) was significantly higher in FH patients examined on statins compared to those without any lipid-lowering treatment (19.9 ± 3.1 vs. 16.4 ± 4.2 respectively, p = 0.022). CONCLUSIONS: This study shows that, in patients with FH, microvascular endothelial-dependent hyperemic response is impaired and inversely correlated to plasma cholesterol levels. Microvascular function was found better in FH patients receiving statins.


Asunto(s)
Colesterol/sangre , Inhibidores de Hidroximetilglutaril-CoA Reductasas/uso terapéutico , Hiperlipoproteinemia Tipo II/tratamiento farmacológico , Microcirculación/efectos de los fármacos , Microvasos/efectos de los fármacos , Piel/irrigación sanguínea , Adulto , Biomarcadores/sangre , Estudios de Casos y Controles , LDL-Colesterol/sangre , Femenino , Predisposición Genética a la Enfermedad , Humanos , Hiperemia/fisiopatología , Hiperlipoproteinemia Tipo II/sangre , Hiperlipoproteinemia Tipo II/genética , Hiperlipoproteinemia Tipo II/fisiopatología , Masculino , Microvasos/fisiopatología , Persona de Mediana Edad , Fenotipo , Resultado del Tratamiento
12.
J Clin Med ; 9(3)2020 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-32121485

RESUMEN

Coronary artery bypass grafting may be associated with several cardiac complications, including ischemia, acute myocardial infarction, arrhythmias, or hemodynamic instability. Accumulating evidence suggests that well-developed coronary collateral circulation may protect against adverse effects, including myocardial ischemia. Assessment of myocardial microvascular perfusion is, therefore, of great clinical interest in beating heart surgery. In this paper, myocardial microvascular perfusion is continuously assessed on the beating heart using laser Doppler flowmetry in consecutive patients who underwent coronary artery bypass grafting procedures. No significant (p = 0.110) differences were found between the averaged perfusion signal (n = 42) at the baseline, during artery occlusion, or after reperfusion (732.4 ± 148.0 vs. 711.4 ± 144.1 vs. 737.0 ± 141.2, respectively). In contrast, significantly different (p < 0.001) mean perfusion signals (n = 12) were found (805.4 ± 200.1 vs. 577.2 ± 212.8 vs. 649.3 ± 220.8) in a subset of patients who presented with hemodynamic instability and myocardial ischemia. Additionally, a strong positive correlation between the plasma levels of high-sensitivity troponin I and perfusion decrease level after artery occlusion was found (r = 0.854, p < 0.001). This study argues that myocardial microvascular perfusion remains constant during coronary artery bypass grafting on the beating heart in advanced coronary artery disease. This phenomenon is most likely due to an extensive coronary collateral circulation.

13.
Medicina (Kaunas) ; 55(4)2019 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-31009994

RESUMEN

Background and objective: Orthostatic hypotension (OH) is a decrease in systolic blood pressure (BP) of 20 mm Hg and in diastolic BP of 10 mm Hg when changing the position from lying to standing. Arterial hypertension (AH), comorbidities and polypharmacy contribute to its development. The aim was to assess the presence of OH and its predictors in asymptomatic chronic kidney disease (CKD) patients. Material and methods: 45 CKD patients with estimated glomerular filtration rate (eGFR) ≤ 60 mL/min/1.73 m2 (CKD+) were examined for signs of OH and its predictors. The results were compared with the control group of 22 patients with eGFR > 60 mL/min/1.73 m2 (CKD-). Asymptomatic patients without ischemic heart disease and previous stroke were qualified. Total blood count, serum creatinine, eGFR, urea, phosphates, calcium, albumins, parathyroid hormone, uric acid, C reactive protein, N-terminal pro b-type natriuretic peptide, lipid profile, and urine protein to creatinine ratio were assessed. Simultaneously, patients underwent echocardiography. To detect OH, a modified Schellong test was performed. Results: OH was diagnosed in 17 out of 45 CKD+ patients (average age 69.12 ± 13.2) and in 8 out of 22 CKD- patients (average age 60.50 ± 14.99). The CKD+ group demonstrated significant differences on average values of systolic and diastolic BP between OH+ and OH- patients, lower when standing. In the eGFR range of 30-60 mL/min/1.73 m2 correlation was revealed between OH and ß-blockers (p = 0.04), in the entire CKD+ group between ß-blockers combined with diuretics (p = 0.007) and ACE-I (p = 0.033). Logistic regression test revealed that chronic heart failure (CHF, OR = 15.31), treatment with ß-blockers (OR = 13.86) were significant factors influencing the presence of OH. Conclusions: Predictors of OH in CKD may include: CHF, treatment with ß-blockers, combined with ACE-I and diuretics.


Asunto(s)
Enfermedades Asintomáticas/epidemiología , Hipotensión Ortostática/epidemiología , Insuficiencia Renal Crónica/epidemiología , Antagonistas Adrenérgicos beta/efectos adversos , Anciano , Anciano de 80 o más Años , Análisis de Varianza , Inhibidores de la Enzima Convertidora de Angiotensina/efectos adversos , Enfermedad Crónica , Comorbilidad , Diuréticos/efectos adversos , Quimioterapia Combinada , Femenino , Insuficiencia Cardíaca/complicaciones , Humanos , Incidencia , Modelos Logísticos , Masculino , Persona de Mediana Edad , Pacientes Ambulatorios , Estadísticas no Paramétricas
15.
Pol Merkur Lekarski ; 44(261): 124-129, 2018 Mar 27.
Artículo en Polaco | MEDLINE | ID: mdl-29601561

RESUMEN

Sarcoidosis is a generalised granulomatous disorder of unknown aetiology. Cardiac involvement may affect conduction system, myocardium, valvular apparatus and pericardium. Clinical spectrum ranges from asymptomatic involvement to sudden cardiac death. Patients with biopsy-proven extracardiac sarcoidosis should be screened for cardiac involvement (standard ECG, 24-hour Holter ECG, echocardiography) and in case of any abnormalities found on these tests, more advanced diagnostic methods should be used. Steroid treatment is still the mainstay of therapy in cardiac sarcoidosis. Several immunosuppresive agents are also effective and used in different combinations with steroids, as well as heart failure treatment (including ACE inhibitors, angiotensin receptor blockers, beta-blockers and diuretics). Advanced heart block requires pacemaker implantation, and implantable cardioverterdefibrillator is an effective treatment in primary and secondary prophylaxis of sudden cardiac death. Heart transplantation is considered in advanced, drug-resistant heart failure or incessant ventricular arrhythmias unresponsive to other forms of therapy.


Asunto(s)
Corticoesteroides/uso terapéutico , Cardiomiopatías/diagnóstico , Sarcoidosis/diagnóstico , Antagonistas de Receptores de Angiotensina/uso terapéutico , Arritmias Cardíacas/etiología , Arritmias Cardíacas/terapia , Cardiomiopatías/complicaciones , Cardiomiopatías/tratamiento farmacológico , Cardiomiopatías/inmunología , Inhibidores de la Colinesterasa/uso terapéutico , Electrocardiografía Ambulatoria , Humanos , Inmunosupresores/uso terapéutico , Imagen por Resonancia Magnética , Monitoreo Fisiológico , Tomografía de Emisión de Positrones , Guías de Práctica Clínica como Asunto , Sarcoidosis/complicaciones , Sarcoidosis/tratamiento farmacológico , Sarcoidosis/inmunología
16.
Cardiol J ; 25(1): 120-127, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-28840593

RESUMEN

BACKGROUND: Endothelial dysfunction is one of the earliest vascular manifestations in the pathogen-esis of cardiovascular disease. Noninvasive, simple, and inexpensive methods of endothelial function assessment are therefore needed. METHODS: Microvascular endothelial function was assessed in coronary artery disease (CAD) patients by flow mediated skin fluorescence (FMSF), based on measurements of reduced form of nicotinamide adenine dinucleotide (NADH) fluorescence intensity during brachial artery occlusion (ischemic re-sponse [IRmax]) and immediately after occlusion (hyperemic response [HRmax]). Additionally, plasma levels of asymmetric dimethylarginine (ADMA) and endothelin-1 (ET-1) were measured to assess the association between biochemical markers and microvascular function evaluated in vivo by FMSF. RESULTS: A significant inverse correlation was found between ADMA levels and hyperemic response (r = -0.534, p = 0.003), while ET-1 levels were inversely related to the ischemic response (r= -0.575, p = 0.001). Both IR and HR were found lowest in patients with advanced CAD and diabetes. When the repeatability of the method was tested, the intraclass correlation coefficient for IRmax and HRmax were 0.985 (p < 0.001) and 0.914 (p < 0.001), respectively. Moreover, in Bland and Altman analysis, both variables IRmax and HRmax showed good agreement in repeated measurements. CONCLUSIONS: In this pilot study, it was demonstrated that NADH fluorescence measured by FMSF device in CAD patients was associated with established plasma endothelial markers, and that both ischemic and hyperemic response were blunted in patients with advanced disease and diabetes. Fur-thermore, FMSF device showed excellent repeatability and good agreement for repeated measurements. However, further study is warranted to confirm these results in a larger patient cohort. (Cardiol J 2018; 25, 1: 120-127).


Asunto(s)
Velocidad del Flujo Sanguíneo/fisiología , Enfermedad de la Arteria Coronaria/fisiopatología , Endotelio Vascular/fisiopatología , Mediciones Luminiscentes/instrumentación , Microcirculación/fisiología , Piel/irrigación sanguínea , Vasodilatación/fisiología , Enfermedad de la Arteria Coronaria/diagnóstico , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto
17.
Microvasc Res ; 113: 60-64, 2017 09.
Artículo en Inglés | MEDLINE | ID: mdl-28529171

RESUMEN

OBJECTIVE: Recent technical developments enable skin fluorescence to be quantified in vivo in humans. The present study aimed at determining whether flow mediated skin fluorescence was reproducible, sensitive to changes within an individual, and if it could differ between patients with coronary artery disease and healthy volunteers. METHODS: First, forearm flow mediated skin fluorescence recorded during and after brachial artery occlusion was assessed following successive forearm occlusion periods (1, 2, 3 and 5min) and expressed as ischemic and hyperemic responses (as % of baseline). Secondly, 3min flow mediated skin fluorescence was assessed before and after 10min local cooling to 15°C. In a third protocol, the inter-day reproducibility of ischemic and hyperemic responses to 3min occlusion was tested at an interval of 7days, and compared between healthy controls and patients with coronary artery disease (CAD). RESULTS: In the first protocol, we observed a time dependent increase in the ischemic and hyperemic responses to occlusion. Next, we observed a lower hyperemic response after local cooling (9.8±4.2 versus 17.8±2.5% respectively, P<0.001), while in contrast, the ischemic response was higher and exhibited greater variability (23±15 versus 11.8±6.4%; P=0.028). In the third protocol, the inter-day reproducibility of flow mediated skin fluorescence for a 3min occlusion period was excellent. The ischemic response was significantly lower in CAD patients than in healthy controls (6.7±4.8% vs 14.7±6.8% respectively, P<0.001). Similarly, the hyperemic response was significantly decreased in the CAD group compared to healthy controls (11.6±3.6% vs 19.5±5.4% respectively, P<0.001). CONCLUSION: We show that quantifying the ischemic and hyperemic flow mediated skin fluorescence is feasible, reproducible, sensitive to acute changes in skin blood flow, and distinguishes patients populations. However, more data are needed to evaluate the correlation with other methods or specific biochemical endothelial markers.


Asunto(s)
Arteria Braquial/fisiología , Enfermedad de la Arteria Coronaria/diagnóstico , Microcirculación , NAD/metabolismo , Piel/irrigación sanguínea , Torniquetes , Extremidad Superior/irrigación sanguínea , Adulto , Biomarcadores/metabolismo , Velocidad del Flujo Sanguíneo , Estudios de Casos y Controles , Enfermedad de la Arteria Coronaria/metabolismo , Enfermedad de la Arteria Coronaria/fisiopatología , Estudios de Factibilidad , Femenino , Humanos , Hiperemia/fisiopatología , Isquemia/fisiopatología , Mediciones Luminiscentes , Masculino , Persona de Mediana Edad , Oxidación-Reducción , Valor Predictivo de las Pruebas , Flujo Sanguíneo Regional , Reproducibilidad de los Resultados , Temperatura Cutánea , Factores de Tiempo
18.
BMC Cardiovasc Disord ; 16(1): 110, 2016 05 26.
Artículo en Inglés | MEDLINE | ID: mdl-27387199

RESUMEN

BACKGROUND: Pulse wave velocity (PWV) is a biomarker for arterial stiffness, clinically assessed by applanation tonometry (AT). Increased use of phase-contrast cardiac magnetic resonance (CMR) imaging allows for PWV assessment with minor routine protocol additions. The aims were to investigate the acquired temporal resolution needed for accurate and precise measurements of CMR-PWV, and develop a tool for CMR-PWV measurements. METHODS: Computer phantoms were generated for PWV = 2-20 m/s based on human CMR-PWV data. The PWV measurements were performed in 13 healthy young subjects and 13 patients at risk for cardiovascular disease. The CMR-PWV was measured by through-plane phase-contrast CMR in the ascending aorta and at the diaphragm level. Centre-line aortic distance was determined between flow planes. The AT-PWV was assessed within 2 h after CMR. Three observers (CMR experience: 15, 4, and <1 year) determined CMR-PWV. The developed tool was based on the flow-curve foot transit time for PWV quantification. RESULTS: Computer phantoms showed bias 0.27 ± 0.32 m/s for a temporal resolution of at least 30 ms. Intraobserver variability for CMR-PWV were: 0 ± 0.03 m/s (15 years), -0.04 ± 0.33 m/s (4 years), and -0.02 ± 0.30 m/s (<1 year). Interobserver variability for CMR-PWV was below 0.02 ± 0.38 m/s. The AT-PWV overestimated CMR-PWV by 1.1 ± 0.7 m/s in healthy young subjects and 1.6 ± 2.7 m/s in patients. CONCLUSIONS: An acquired temporal resolution of at least 30 ms should be used to obtain accurate and precise thoracic aortic phase-contrast CMR-PWV. A new freely available research tool was used to measure PWV in healthy young subjects and in patients, showing low intra- and interobserver variability also for less experienced CMR observers.


Asunto(s)
Aorta/fisiopatología , Determinación de la Presión Sanguínea/métodos , Enfermedades Cardiovasculares/diagnóstico , Interpretación de Imagen Asistida por Computador , Imagen por Resonancia Cinemagnética/métodos , Fantasmas de Imagen , Análisis de la Onda del Pulso/métodos , Adolescente , Adulto , Anciano , Aorta/diagnóstico por imagen , Velocidad del Flujo Sanguíneo , Enfermedades Cardiovasculares/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Curva ROC , Reproducibilidad de los Resultados , Adulto Joven
19.
Acta Dermatovenerol Croat ; 24(4): 261-267, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28128076

RESUMEN

Psoriasis is a chronic inflammatory skin disorder associated with increased cardiovascular risk. Aim of this work was to evaluate the association between psoriasis and chosen cardiovascular risk factors, echocardiographic parameters, and carotid intima-media thickness. A total of 50 patients with psoriasis and 50 controls were enrolled in the study. Psoriasis area severity index was calculated in the study group. Systolic and diastolic blood pressure, body mass index, waist circumference, lipids, fasting glucose, and D-dimer levels were assessed in all patients. In addition, echochardiographic parameters and carotid intima-media thickness were measured. Patients with psoriasis had higher blood pressure (P=0.001), elevated triglycerides (P=0.0218), lower high-density lipoprotein cholesterol (HDL-C) (P=0.0014), elevated D-dimer levels (p=0.0009), and were more frequently overweight (P=0.0198) in comparison to controls. There were no differences in echocardiographic parameters and carotid intima-media thickness between the psoriasis and control groups. Moreover, a positive correlation between psoriasis area severity index and blood pressure was observed (P=0.0088). The study confirmed that psoriasis is associated with increased cardiovascular risk. The association between psoriasis, intima-media thickness, and echocardiographic parameters should be evaluated in large prospective studies.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico por imagen , Enfermedades Cardiovasculares/epidemiología , Grosor Intima-Media Carotídeo , Hipertensión/fisiopatología , Psoriasis/epidemiología , Adulto , Distribución por Edad , Enfermedades Cardiovasculares/patología , Estudios de Casos y Controles , Comorbilidad , Intervalos de Confianza , Ecocardiografía , Femenino , Humanos , Hipertensión/epidemiología , Incidencia , Metabolismo de los Lípidos/fisiología , Masculino , Persona de Mediana Edad , Polonia/epidemiología , Pronóstico , Psoriasis/patología , Valores de Referencia , Factores de Riesgo , Índice de Severidad de la Enfermedad , Distribución por Sexo , Estadísticas no Paramétricas , Relación Cintura-Cadera
20.
Perit Dial Int ; 36(3): 257-61, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26475845

RESUMEN

UNLABELLED: ♦ BACKGROUND: Biocompatible fluids for peritoneal dialysis (PD) have been introduced to improve dialysis and patient outcome in end-stage renal disease. However, their impact on hydration status (HS), residual renal function (RRF), and dialysis adequacy has been a matter of debate. The aim of the study was to evaluate the influence of a biocompatible dialysis fluid on the HS of prevalent PD patients. ♦ METHODS: The study population consisted of 18 prevalent PD subjects, treated with standard dialysis fluids. At baseline, 9 patients were switched to a biocompatible solution, low in glucose degradation products (GDPs) (Balance; Fresenius Medical Care, Bad Homburg, Germany). Hydration status was assessed through clinical evaluation, laboratory parameters, echocardiography, and bioimpedance spectroscopy over a 24-month observation period. ♦ RESULTS: During the study period, urine volume decreased similarly in both groups. At the end of the evaluation, there were also no differences in clinical (body weight, edema, blood pressure), laboratory (N-terminal pro-brain natriuretic peptide, NTproBNP), or echocardiography determinants of HS. However, dialysis ultrafiltration decreased in the low-GDP group and, at the end of the study, equaled 929 ± 404 mL, compared with 1,317 ± 363 mL in the standard-fluid subjects (p = 0.06). Hydration status assessed by bioimpedance spectroscopy was +3.64 ± 2.08 L in the low-GDP patients and +1.47 ± 1.61 L in the controls (p = 0.03). ♦ CONCLUSIONS: The use of a low-GDP biocompatible dialysis fluid was associated with a tendency to overhydration, probably due to diminished ultrafiltration in prevalent PD patients.


Asunto(s)
Soluciones para Diálisis , Fallo Renal Crónico/terapia , Diálisis Peritoneal , Desequilibrio Hidroelectrolítico/epidemiología , Adulto , Espectroscopía Dieléctrica , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Ultrafiltración
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...